A NEW INJECTION ACTUATION PRESSURE CONTROL VALVE CONNECTOR INCREASES ENGINE OPERATION Caterpillar


`
A NEW INJECTION ACTUATION PRESSURE CONTROL VALVE CONNECTOR INCREASES ENGINE OPERATION [TIBU3776]
ELECTRICAL AND STARTING SYSTEM
WIRING GP
A NEW INJECTION ACTUATION PRESSURE CONTROL VALVE CONNECTOR INCREASES ENGINE OPERATION

CONFIDENTIAL TIBU3776

TECHNICAL INFORMATION BULLETIN

JAN. 15th, 2003

EXCAVATORS

WHEEL LOADERS

ENGINES

322C: (EMR, MAR);
325C: (CRB, CSJ, JLC, JLD, DTF)
950G II: (AYL, AYB);
962G II: (AYE, BAB)
3126B: (BMA)

 

Component Code(s) 1408

SUBJECT: A NEW INJECTION ACTUATION PRESSURE CONTROL VALVE CONNECTOR INCREASES ENGINE OPERATION

PROBLEM:

The injection actuation pressure (IAP) control valve connector may have been assembled incorrectly on some 3126B engine harnesses. This can lead to intermittent engine operation or can cause the engine to stop.

SOLUTION:

If your machine exhibits symptoms of intermittent engine operation or abruptly stopping, the IAP control valve connector should be disconnected from the machine, examined for solenoid contact problems and re-installed using a correct procedure.

Procedure for installing the IAP control valve connector

This procedure will describe how to properly install the 232-4367 Harness.

Required Parts

Qty

Part Number

Description

1

232-4367

Harness

  1. Procure the part that is listed in the table.
  2.  

     

    Illustration 1. Left Side of a 3126B Engine on a D6N.
    (1) IAP Control Valve
    (2) IAP Control Valve Connector

    Note: Illustration 1 is from a D6N that is equipped with a 3126B for photographical purposes. The location of the IAP Control Valve is the same for your machine.

  3. Disconnect the IAP control valve connector (2) from the IAP Control Valve (1). See Illustration 1.
  4. Cut the two wires directly behind the connector.
  5. Using wire strippers, strip the ends of the two wires.
  6.  

     

  7. Install the 232-4367 Harness, by crimping the stripped wires inside the splice.
  8. Note: Take care to connect the pink wire to the pink wire on one hand and the purple wire to the purple wire on the other hand.

  9. Heat both heat shrinkable tubes in order to insulate both the splices.
  10. Reconnect the repaired harness to the IAP Control Valve (1).

 

 

 

 

 

 

 

 

 

 

 

 

COPYRIGHT 2003 AVSpare
ALL RIGHTS RESERVED

Information System:

FAULT CODE MAY APPEAR WHILE PERFORMING PI10199
THE WHEEL SPINDLES MAY FAIL ON CERTAIN 216 AND 226 SKID STEER LOADERS
Fuel Level Sensors May Break Loose From Float Arm
TRANSMISSION PRESSURE CONTROL VALVE MANIFOLD
Fleet/Key Configuration Issue Using Cat ET Version 2002B
QUICK COUPLER ASSEMBLY ON SOME SSL'S & MTL'S MAY BE TOO WIDE
REPORT ALL PROBLEMS OF INTERFERNECE THAT MAY BE EXPERIENCED BETWEEN THE NEW HYDRAULIC QUICK COUPLERS AND WORK TOOLS
THE NEW 212-6590 IDLER WHEELS MAY MAKE CONTACT WITH THE UNDERCARRIAGE SCRAPERS
Check Valve may be Incorrectly Installed in the Cooling Fan Oil Return to Tank Line
Bypass Schedule May Be Affected when Machine Security System (MSS) Automatically Adjusts to North American Daylight Savings Time
EXCESSIVE WEAR IN THE 3524 ENGINES IN 797 OFF-HIGHWAY TRUCKS
THE STEERING WARNING LAMP REMAINS ON
NEW CRANKSHAFT SEALS FOR THE FRONT AND FOR THE REAR ARE NOW IN PRODUCTION BUT ARE NOT AVAILIBLE TO BE OREDERD AT THIS TIME
Flashing New Software When Electronic Control Module (ECM) or Injectors Are Replaced
MODIFICATION TO PREVENT OIL BLOWING THROUGH THE 165-8460 VENT AS.
Landfill Compactor Wheel Tip Clearance
THE AUTOMATIC LUBRICATION SYSTEM REQUIRES AN ADDITIONAL ORIFICE
Use of the 9Y-5710 Auxiliary Sea Water Pump in 3500 and 3500B applications
New Steering Cylinders have Collar Assemblies on Rods
The Navigator Touchscreen Display Can Remain in a Black Screen State when the �Power On� LED Is Illuminated
Cracking of PMG Capacitor Cases Due to Prolonged Elevated Temperatures in Certain High Voltage Generators (Kato).
Loose Connections on Voltage Regulators Can Lead to Above Normal Voltage Output and Regulator Failure
Improvements To The Heating Ventilating And Air Conditioning (HVAC) System Increase Operator Comfort
PRIMER/PAINT ON THE FINISHED SURFACE OF CYLINDER RODS FOR SOME WORK TOOLS