Personal injury or death can result from sudden machine movement. Sudden movement of the machine or release of air pressure or oil pressure can cause injury to persons on or near the machine. To help prevent possible injury before testing and adjusting any air system or hydraulic system, perform the procedure in the Testing and Adjusting, "General Information" section. |
![]() |
Perform the visual checks before you troubleshoot a problem. Make sure that the transmission is in neutral and stop the engine. During the visual checks, use a magnet to separate ferrous particles (iron and steel) from nonferrous particles (bronze, rubber, and paper).
Check: Check the oil level in the hoist, torque converter and brake hydraulic tank.
![]() | |
Illustration 1 | g00647477 |
(1) Hoist, torque converter and brake hydraulic tank |
![]() | |
Illustration 2 | g00647479 |
(2) Brake oil cooler |
![]() | |
Illustration 3 | g00690434 |
(3) Hoist, torque converter, and brake oil cooler |
Check the oil level in hoist, torque converter, and brake hydraulic tank (1). Look for air or water in the sight gauge. Many problems are caused by low oil level or air in the oil. Add oil to hoist, torque converter, and brake tank (1) if the oil level is low. See the Operation and Maintenance Manual for the correct type of oil.
Problem: There is an indication of water in the oil.
Probable Cause
- A failure of brake oil cooler (2)
- A failure of hoist, torque converter, and brake oil cooler (3)
Problem: There is an indication of air in the oil.
Probable Cause
- There is a leak in the oil lines. See "Check for oil leakage".
Problem: The oil level is too low.
Probable Cause
- There is a leak in the oil lines. See "Check for oil leakage". Add oil before you perform any tests.
- Brake cooling oil can leak into the final drive. Check the oil level in each final drive.
Check: Check for oil leakage.
Inspect all oil lines, all hoses and all connections for damage or for leaks. Look for oil on the ground under the machine.
Note: If oil can leak out of a fitting or out of a connection, air can enter the system. Air in the system can be as harmful as having too little oil.
Check: Check the parking brake release oil filter.
![]() | |
Illustration 4 | g00647480 |
(4) Parking brake release oil filter |
Remove the element of parking brake release oil filter (4). Inspect elements for foreign material. Cut the filter open, if necessary.
Note: Parking brake release oil filter (4) has an oil bypass valve. The bypass valve allows the oil to bypass the filter elements whenever the pressure difference between the inlet oil and the outlet oil becomes too high. Any oil that does not flow through the filter element goes directly into the hydraulic circuit. Dirty oil can cause sticking valves and restrictions in valve orifices.
The pressure setting of the bypass valve in parking brake release oil filter (4) is 248 ± 21 kPa (36 ± 3 psi).
Problem: Rubber particles are found.
Probable Cause
- Seal failure
- Hose failure
Problem: Shiny steel particles are found.
![]() | |
Illustration 5 | g00647484 |
(5) Torque converter scavenge section (6) Torque converter charging pump section (7) Parking brake release pump section (8) Brake cooling pump section |
Probable Cause
- There is a mechanical failure of parking brake release pump section (7) .
Check: Check the torque converter charging oil filter
![]() | |
Illustration 6 | g00647485 |
Remove torque converter charging oil filter (9). Inspect torque converter charging oil filter (9) for foreign material. Cut the filter open, if necessary.
Note: Torque converter charging oil filter (9) has an oil bypass valve. The bypass valve allows the oil to bypass the filter element or the screen whenever the pressure difference between the inlet oil and the outlet oil becomes too high. Any oil that does not flow through the filter element or the screen goes directly into the hydraulic circuit. Dirty oil can cause sticking valves and restrictions in valve orifices.
The pressure setting of the bypass valve in torque converter charging oil filter (9) is 140 kPa (20 psi).
Problem: Rubber particles are found.
Probable Cause
- Seal failure
- Hose failure
Problem: Shiny steel particles are found.
![]() | |
Illustration 7 | g00647484 |
(5) Torque converter scavenge section (6) Torque converter charging pump section (7) Parking brake release pump section (8) Brake cooling pump section |
Probable Cause
- A mechanical failure of the torque converter charging pump section (6)
Check: Check the torque converter scavenge screen.
![]() | |
Illustration 8 | g00647747 |
(10) Torque converter scavenge screen |
Make sure that the oil has been drained from the hydraulic oil tank and from the torque converter for the next check.
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "AVSpare Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on AVSpare products. Dispose of all fluids according to local regulations and mandates. |
Remove torque converter scavenge screen (10). Inspect torque converter scavenge screen (10) for foreign material or restrictions.
Problem: Rubber particles are found.
- Seal failure
- Hose failure
Problem: Shiny steel particles are found.
![]() | |
Illustration 9 | g00647484 |
(5) Torque converter scavenge section (6) Torque converter charging pump section (7) Parking brake release pump section (8) Brake cooling pump section |
![]() | |
Illustration 10 | g00647483 |
(11) Hoist pump (12) Pump drive |
Probable Cause
- There is a mechanical failure of pump drive (12) .
- A mechanical failure of parking brake release pump section (7). Refer to "Check the parking brake release oil filter".
- There is a mechanical failure of torque converter charging pump section (6). Refer to "Check the torque converter charging oil filter".
Problem: Aluminum particles are found.
Probable Cause
- There is mechanical failure of the torque converter.
Problem: Black fiber is found.
Probable Cause
- There is a worn lockup clutch in the torque converter.
Check: Check the screens for the brake oil coolers.
![]() | |
Illustration 11 | g00647787 |
(13) Brake oil cooler screen |
![]() | |
Illustration 12 | g00647788 |
(14) Hoist, torque converter, and brake oil cooler screen |
Remove screens (13) and (14) for the brake oil coolers. Inspect screens (13) and (14) .
Problem: Rubber particles are found.
Probable Cause
- Seal failure
- Hose failure
Problem: Shiny steel particles are found in the screen for the hoist, torque converter, and brake cooler.
![]() | |
Illustration 13 | g00647484 |
(5) Torque converter scavenge section (6) Torque converter charging pump section (7) Parking brake release pump section (8) Brake cooling pump section |
![]() | |
Illustration 14 | g00647483 |
(11) Hoist pump (12) Pump drive |
Probable Cause
- A mechanical failure of torque converter charging pump section (6). Refer to "Check the torque converter charging oil filter".
Problem: Large quantities of aluminum particles are found in the screen for the hoist, torque converter, and brake oil cooler.
Probable Cause
- Mechanical failure of the torque converter
Problem: Black fiber is found in the screen for the hoist, torque converter, and brake oil cooler.
Probable Cause
- A worn lockup clutch in the torque converter
Problem: Shiny steel particles are found in the brake oil cooler screen.
![]() | |
Illustration 15 | g00647483 |
(11) Hoist pump (12) Pump drive |
Probable Cause
- There is a mechanical failure of the hoist pump (11) .
Problem: Aluminum particles are found in the brake oil cooler screen.
![]() | |
Illustration 16 | g00647483 |
(11) Hoist pump (12) Pump drive |
Note: A small amount of aluminum particles are normal.
Probable Cause
- There is a mechanical failure of hoist pump (11). Refer to "Check the screens for the brake oil coolers".
Check: Check the inside of the hydraulic tank.
![]() | |
Illustration 17 | g00916445 |
(13) Hoist suction screen (14) Torque converter and brake suction screen |
Drain the oil from the hydraulic tank. Remove the outer cover from the hydraulic tank. Inspect the bottom of the hydraulic tank for debris. Remove the hoses from the back of the hydraulic tank in order to remove suction screens (13) and (14) and clean the suction screens.
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "AVSpare Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on AVSpare products. Dispose of all fluids according to local regulations and mandates. |
Problem: Rubber particles are found.
Probable cause
- Seal failure
- Hose failure
Problem: Shiny steel particles are found.
![]() | |
Illustration 18 | g00647484 |
(5) Torque converter scavenge section (6) Torque converter charging pump section (7) Parking brake release pump section (8) Brake cooling pump section |
![]() | |
Illustration 19 | g00647483 |
(11) Hoist pump (12) Pump drive |
Probable Cause
- There is a mechanical failure of torque converter scavenge pump section (5) .
- There is a mechanical failure of parking brake release pump section (7). Refer to "Check the parking brake release oil filter".
- There is a mechanical failure of the torque converter charging pump section (6). Refer to "Check the torque converter charging oil filter".
- There is a mechanical failure of the pump drive (12). See "Check the torque converter scavenge screen".
Problem: Aluminum particles are found.
Probable Cause
- There is a mechanical failure of the torque converter. Refer to "Check the torque converter scavenge screen".
Problem: A large quantity of aluminum particles are found.
![]() | |
Illustration 20 | g00647483 |
(11) Hoist pump (12) Pump drive |
Note: A small amount of aluminum particles are normal.
Probable Cause
- There is a mechanical failure of the hoist pump (11) .
Problem: Black fiber is found.
Probable Cause
- Failure of the wheel brakes
- There is a worn lockup clutch in the torque converter. See "Check the torque converter scavenge screen" and "Check the screens for the brake oil coolers".
Problem: Shiny steel particles and/or chrome particles are found.
Probable Cause
- There is a mechanical failure of a hydraulic cylinder and/or a cylinder rod. Inspect the cylinder rods for scoring.
Note: If any of the above particles are found during any visual checks, all components of the hoist, of the torque converter, and of the brake cooling system must be cleaned. Do not use any damaged parts. Damaged parts must be replaced with new parts.