Removal Procedure
![]() |
Fuel leaked or spilled onto hot surfaces or electrical components can cause a fire. To help prevent possible injury, turn the start switch off when changing fuel filters or water separator elements. Clean up fuel spills immediately. |
![]() |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "AVSpare Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on AVSpare products. Dispose of all fluids according to local regulations and mandates. |
Note: Check the O-ring seals, the gaskets, and the seals for wear or for damage. Replace the components, if necessary.
- Remove bolts (1). Remove fuel priming pump (2) and the gasket.
![]() | |
Illustration 1 | g00915173 |
Installation Procedure
- Install the gasket and fuel priming pump (2). Install bolts (1). Tighten bolts (1) to a torque of 27 ± 8 N·m (20 ± 6 lb ft).
![]() | |
Illustration 2 | g00915173 |